Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: Samsung ICR18650-29E
Brand: Samsung
Packaging: original box or special single/dual smaller box
Transportation: Ocean,Air
Place of Origin: Korea
HS Code: 85076000
Port: Hong Kong,Shenzhen
Payment Type: T/T,Paypal,Western Union
Incoterm: FOB
The Samsung ICR18650-29E cell is very good 18650 Battery cells for usual application those doesnot excess 3A draw. It provides a alternative other then 26F cell which bring 300mAh capacity while a bit more in price accordingly.
lygte-info testing:
Nominal Specifications
3.1. Nominal Capacity 2,850mAh (0.2C, 2.50V discharge)
3.1.1. Typical Capacity 2,850mAh (0.2C, 2.50V discharge)
3.1.2. Minimum Capacity 2,750mAh (0.2C, 2.50V discharge)
3.2. Charging Voltage 4.20 ± 0.05 V
3.3. Nominal Voltage 3.65V (0.2C discharge)
3.4. Charging Method CC-CV
(constant voltage with limited current)
3.5. Charging Current Standard charge: 1,375mA
3.6. Charging Time Standard charge: 3hours
3.7. Max. Charge Current 2750mA (not for cyclelife)
3.8. Max. Discharge Current 2,750mAh (continuous discharge)
8250mAh (not for continuous discharge)
3.9. Discharge Cut-off Voltage 2.50V
3.10. Cell Weight (max. (g)) 48g
3.11. Cell Dimension
Diameter(max.) : 18.40 mm
Height(max) : 65.00 mm
3.12. Operating Temperature
(Cell Surface Temperature)
Charge: 0 to 45°C
Discharge: -20 to 60°C
3.13. Storage Temperature
1 year : -20~25°C (1*)
3 months : -20~45°C (1*)
1 month : -20~60°C (1*)
9. Safety
9.1 Overcharge Test
Test method: To charge the standard charged cell with 12V and 2,750mA at 25°C
for 2.5 hours.
Criteria: No fire, and no explosion.
9.2 External Short-circuit Test
Test method: To short-circuit the standard charged cell by connecting positive and
negative terminal by less than 80±20mΩwire for 3 hours.
Criteria: No fire, and no explosion.
9.3 Reverse Charge Test
Test method: To charge reversely the standard charged cell with charge current
2,750mA for 2.5 hours.
Criteria: No fire, and no explosion.
9.4 Heating Test
Test method: To heat the standard charged cell at heating rate of 5°C per minute up to
130°C and keep the cell in oven for 60 minutes.
Criteria: No fire, and no explosion.
Product Categories : Rechargeable Batteries > 18650 Battery
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.