Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Model No.: Samsung ICR18650-29E
Brand: Samsung
Packaging: original box or special single/dual smaller box
Transportation: Ocean,Air
Place of Origin: Korea
HS Code: 85076000
Port: Hong Kong,Shenzhen
Payment Type: T/T,Paypal,Western Union
Incoterm: FOB
The Samsung ICR18650-29E cell is very good 18650 battery cells for usual application those doesnot excess 3A draw. It provides a alternative other then 26F cell which bring 300mAh capacity while a bit more in price accordingly.
lygte-info testing:
Nominal Specifications
3.1. Nominal Capacity 2,850mAh (0.2C, 2.50V discharge)
3.1.1. Typical Capacity 2,850mAh (0.2C, 2.50V discharge)
3.1.2. Minimum Capacity 2,750mAh (0.2C, 2.50V discharge)
3.2. Charging Voltage 4.20 ± 0.05 V
3.3. Nominal Voltage 3.65V (0.2C discharge)
3.4. Charging Method CC-CV
(constant voltage with limited current)
3.5. Charging Current Standard charge: 1,375mA
3.6. Charging Time Standard charge: 3hours
3.7. Max. Charge Current 2750mA (not for cyclelife)
3.8. Max. Discharge Current 2,750mAh (continuous discharge)
8250mAh (not for continuous discharge)
3.9. Discharge Cut-off Voltage 2.50V
3.10. Cell Weight (max. (g)) 48g
3.11. Cell Dimension
Diameter(max.) : 18.40 mm
Height(max) : 65.00 mm
3.12. Operating Temperature
(Cell Surface Temperature)
Charge: 0 to 45°C
Discharge: -20 to 60°C
3.13. Storage Temperature
1 year : -20~25°C (1*)
3 months : -20~45°C (1*)
1 month : -20~60°C (1*)
9. Safety
9.1 Overcharge Test
Test method: To charge the standard charged cell with 12V and 2,750mA at 25°C
for 2.5 hours.
Criteria: No fire, and no explosion.
9.2 External Short-circuit Test
Test method: To short-circuit the standard charged cell by connecting positive and
negative terminal by less than 80±20mΩwire for 3 hours.
Criteria: No fire, and no explosion.
9.3 Reverse Charge Test
Test method: To charge reversely the standard charged cell with charge current
2,750mA for 2.5 hours.
Criteria: No fire, and no explosion.
9.4 Heating Test
Test method: To heat the standard charged cell at heating rate of 5°C per minute up to
130°C and keep the cell in oven for 60 minutes.
Criteria: No fire, and no explosion.